structure dynamic-safety-factor
command
Syntax
- structure dynamic-safety-factor f
Set the safety factor for dynamic analysis. This is the factor by which the timestep necessary for solution stability of the structural element computations will be multiplied. The actual timestep used will be the minimum of the structural element timestep and the timesteps for the zones and other active modules (e.g., fluid, thermal or creep). The dynamic safety factor is multiplied into the calculated critical stable dynamic timestep for all nodes based on their accumulate stiffness contribution. The default is 2.0, and the minimum allowed is 1.2
Was this helpful? ... | Itasca Software © 2024, Itasca | Updated: Oct 31, 2024 |