block.subcontact.state
Syntax
- i = block.subcontact.state(bscp)
- block.subcontact.state(bscp) = i
Get/set the subcontact state indicator.
The subcontact failure state is represented by a variable with 64 bits. Each bit refers to a potential state. Different joint constitutive models will have different potential states (see Constitutive Models in 3DEC). The potential states for the Mohr-Coulomb model are shown in the table below.
MC Failure States |
Value |
Label |
---|---|---|
Failure in shear now |
1 |
slip-n |
Failure in tension now |
2 |
tension-n |
Failure in shear in the past |
4 |
slip-p |
Failure in tension in the past |
8 |
tension-p |
Combinations of states are possible by turning on different bits. For example, a subcontact that failed in tension in the past and is shearing now would have a state value of 8 + 1 = 9. A value of 0 indicates no failure (elastic).
Was this helpful? ... | Itasca Software © 2024, Itasca | Updated: Aug 13, 2024 |