rblock damping
command
Syntax
- rblock damping <keyword>
-
Specify local (the default) or combined damping. If a local damping coefficient is specified for rigid blocks with the
rblock attribute
command then local damping is active. This command must be given to activate combined damping contributions, or to deactivate combined damping.- combined
Specify combined damping. Combined damping adds a damping force to the translational and rotational equations of motion composed of contributions related to: 1) changes in the sign of the velocity and 2) changes in the sign of the total force. The local damping coefficient is used as set by the
rblock attribute
command. The formulation is described in detail here and only applies to rigid blocks.
- local
Specify local damping (the default). Local damping adds a damping force to the translational and rotational equations of motion only when the sign of the velocity changes for each degree of freedom. The local damping formulation is described in here.