structure damping command
Syntax
- structure damping keyword
Primary keywords:
Set the structural element logic damping scheme. The values of this setting can be printed using the
structure list information
command. The following keywords are available:- combined-local
sets the damping scheme used by the structural element logic to combined-local damping. The local damping constants are stored separately for each node and set by the command
structure node damping-local
.
- local
sets the damping scheme used by the structural element logic to local damping. This is the default setting for static mode. The local-damping constants are stored separately for each node and set by the command
structure node damping-local
.
- none
sets the damping scheme used by the structural element logic to no damping. This is the default setting for dynamic mode.
Was this helpful? ... | PFC 6.0 © 2019, Itasca | Updated: Nov 19, 2021 |