structure link tolerance-contact
command
Syntax
- structure link tolerance-contact f
Set the tolerance used when establishing node-to-zone links. A node is considered to be in a zone if it is within a distance \(d\) of the zone boundary, where \(d\) equals f times zone size (taken as the maximum \(x\)-, \(y\)-, or \(z\)-dimension (\(x\)-, or \(y\)-dimension in 2D) of the zone bounding box). Nodes that are used by elements with their sliding flag
on
will utilizestructure link tolerance-slide
instead of f when attempting to update the zone interpolation point of an existing link. By default, f equals 1 × 10-5.