zone fluid command
Syntax
- zone fluid keyword
Primary keywords:
active biot cmodel fastflow fastflow-relaxation implicit list property permeability dip dip-direction permeability-1 permeability-2 permeability-3 permeability-xx permeability-xy permeability-xz permeability-yy permeability-yz permeability-zz rotation property-distribution saturation-tolerance time-total track zone-based-pp
This command sets parameters for a groundwater fluid flow analysis. These commands are only available after a
model configure fluid
command. These parameters apply to zones only, other model elements may have different values.- active b
The fluid process is on for zones, by default, when the
model configure fluid
command is given. Specify active off to suppress the fluid calculation for zones. Generally this command is unnecessary and is slaved to thezone fluid active
setting.
- biot b
The fluid-flow calculation uses the Biot coefficient, α, and the Biot modulus, M, if on. If off, then the fluid modulus, Kf , and porosity, n, are used and α = 1. The default is off. See Biot Coefficient and Biot Modulus.
- cmodel keyword
Associates a fluid constitutive model with specified zones in the grid. It also allows querying of properties and states of constitutive models.
- assign keyword <range>
assigns a fluid model to all zones in the
range
. This keyword may only be given if the model is configured for fluid calculations (seemodel configure fluid
). Fluid models are described in Grid Configured for Fluid Flow.- anisotropic
Assign the anisotropic flow model.
- isotropic
Assign the isotropic flow model.
- null
Assign the null fluid model.
- list
List the available fluid constitutive models and their properties.
- fastflow b
Turns the fastflow solution scheme on and off. See Fully Saturated Fast Flow.
- fastflow-relaxation f
Sets the relaxation parameters used in the fastflow solution scheme.
- implicit b
The implicit solution scheme in the fluid flow model is turned on or off. The default is off.
- list
- information
Outputs current configuration settings and status information for the fluid model.
- property keyword <range>
Assigns properties for the fluid flow constitutive models of all zones in the rnage. Any number of name value pairs may be assigned. The type of the value a must match the type expected by the property s. Any constitutive model that has a matching property name will be assigned the value.
- biot f
Biot coefficient (grain compressibility), \(\alpha\). The default is 1.0.
- porosity f
Porosity, \(n\). The default is 0.5.
- undrained-thermal-coefficient f
Undrained thermal coefficient, \(\beta\).
Isotropic Fluid Flow:
- permeability f
Isotropic permeability, \(k\). The permeability used in FLAC3D is defined as the conventional hydraulic Permeability divided by the unit weight of water. Permeability must be non-zero if the command
zone fluid active
on applies.
Anisotropic Fluid Flow:
- dip f
Principal permeability plane dip angle (in degrees).
- dip-direction f
Principal permeability plane dip direction angle (in degrees).
- permeability-1 f
Principal permeability value.
- permeability-2 f
Principal permeability value.
- permeability-3 f
Principal permeability value.
- permeability-xx f
xx-component permeability.
- permeability-xy f
xy-component permeability.
- permeability-xz f
xz-component permeability.
- permeability-yy f
yy-component permeability.
- permeability-yz f
yz-component permeability.
- permeability-zz f
zz-component permeability.
- rotation f
Principal permeability plane rotation angle (in degrees).
- property-distribution s akeyword <range>
Assigns a single property name to the fluid flow constitutive models of all zones in the range. The property value may be varied in space by using the following optional keyword values.
- deviation-gaussian f
A gaussian distribution is used to assign the value randomly, with a mean value of a and a standard deviation of f. This keyword only applies to float type property values.
- deviation-uniform f
A uniform distribution is used to assign the value randomly, with a mean value of a and a standard deviation of f. This keyword only applies to float type property values.
- gradient v <origin v >
Apply a gradient to the property value. This keyword only applies to float type property values.
- vary v
Apply a linear variation to the property value. This keyword only applies to float type property values.
- saturation-tolerance f
The effect of saturation changes to gridpoints is only applied when the accumulated saturation change is greater than this value. This is done for efficiency of calculation. The default value is 1x10:exp:\(-3\)
- time-total f
Specifies the accumulated zone fluid time, defined as the sum of all the timesteps over which zone fluid is active. Once set, fluid time will continue to accumulate with subsequent cycles.
- track keyword
The TRACK command places a particle in the grid at the location specified. The particle flows with the fluid and maintains a record of its path over a finite period of time. The grid must be configured for fluid flow (see
model configure fluid
), and the zone must have a non-null fluid model in order for a particle to exist in a zone. The particle is not created (and no error message is output) if the location does not map into a zone with these specifications. The particles have no mass and do not influence the flow or mechanical behavior in any way; they are simply carried along by the fluid and record its motion. Several TRACK commands may be given, at different times, if desired. See the data files in One-Dimensional Filling of a Porous Region for an example of particle track usage. Location and keywords are given as follows.- create keyword
Create one or more particles in zones. The location and number of the particles created are controlled by the following keywords. The <[zonefluidoptions]> following can be used to specify attributes on the created particles.
- point v ... <[zonefluidoptions]>
Place a particle in the grid at the specified location v. For each vector value given, another particle will be created.
- line keyword ... <[zonefluidoptions]>
Add particles to the grid along a line.
- begin v
Specify the start position of the line. The default value is (0,0,0).
- end v
Specify the end position of the line. The default value is (0,0,0).
- plane keyword ... <[zonefluidoptions]>
Add particles to the grid along a plane defined by two lines.
- begin v
Specifies the shared start point of both lines that will define the plane. The default value is (0,0,0).
- end-1 v
Specifies end of the first line. The default value is (0,0,0).
- end-2 v
Specifies end of the second line. The default value is (0,0,0).
- group s keyword <range>
Assign or remove groups to particles in the range. Use of the group logic is described in Group.
- remove
Remove the group s from particles within the given range. This does not remove the particles themselves.
- list <path>
lists summary information about tracking particles. If the path keyword is omitted, the current particle position information is output. If the path keyword is included, then particle path information is output.
- zone-based-pp b
Indicates that pore-pressures should be retrieved directly from the zone, rather than averaged from the gridpoints. Zone pore pressures must be assigned manually via FISH, using the
zone.pp
intrinsic.
Keyword Block
Zone Fluid Track Create Modifiers
At the time of particle creation the following additional configuration settings may optionally be supplied. They apply to the keywords:
line
,plane
andpoint
.- group s1 <slot s2 >
Assign the created particles to the group s1 and (if supplied) assign that group to slot s2. By default the slot name will be Default.
[DR: please check that “see —- ” links here land where they should]
Was this helpful? ... | PFC 6.0 © 2019, Itasca | Updated: Nov 19, 2021 |